<?xml version="1.0" encoding="UTF-8"?> <rss
version="2.0"
xmlns:content="http://purl.org/rss/1.0/modules/content/"
xmlns:wfw="http://wellformedweb.org/CommentAPI/"
xmlns:dc="http://purl.org/dc/elements/1.1/"
xmlns:atom="http://www.w3.org/2005/Atom"
xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
> <channel><title>CsanyiGroup &#187; siemens</title> <atom:link href="http://www.csanyigroup.com/tag/siemens/feed" rel="self" type="application/rss+xml" /><link>http://www.csanyigroup.com</link> <description>Electrical engineering portal</description> <lastBuildDate>Mon, 22 Aug 2011 14:01:32 +0000</lastBuildDate> <language>en</language> <sy:updatePeriod>hourly</sy:updatePeriod> <sy:updateFrequency>1</sy:updateFrequency> <generator>http://wordpress.org/?v=3.0.3</generator> <item><title>Siemens MV Topic &#8211; Loss Of Vacuum</title><link>http://www.csanyigroup.com/siemens-mv-topic-loss-of-vacuum</link> <comments>http://www.csanyigroup.com/siemens-mv-topic-loss-of-vacuum#comments</comments> <pubDate>Wed, 24 Mar 2010 20:39:56 +0000</pubDate> <dc:creator>ecsanyi</dc:creator> <category><![CDATA[Medium Voltage]]></category> <category><![CDATA[Technical Articles]]></category> <category><![CDATA[ansi]]></category> <category><![CDATA[circuit breaker]]></category> <category><![CDATA[contacts]]></category> <category><![CDATA[interrupter]]></category> <category><![CDATA[interrupting]]></category> <category><![CDATA[loss]]></category> <category><![CDATA[magnetic]]></category> <category><![CDATA[mttf]]></category> <category><![CDATA[phase]]></category> <category><![CDATA[pole]]></category> <category><![CDATA[short circuit]]></category> <category><![CDATA[siemens]]></category> <category><![CDATA[vacuum]]></category> <guid
isPermaLink="false">http://www.csanyigroup.com/?p=1667</guid> <description><![CDATA[If a vacuum interrupter should lose vacuum, several operating situations should be considered: 1. With contacts open 2. When closing 3. When closed and operating normally 4. When opening and interrupting normal current 5. When opening and interrupting a fault. Cases 1, 2 and 3 are relatively straightforward. Generally, the system sees no impact from [...]]]></description> <wfw:commentRss>http://www.csanyigroup.com/siemens-mv-topic-loss-of-vacuum/feed</wfw:commentRss> <slash:comments>2</slash:comments> </item> <item><title>Gas-Insulated Switchgear Type 8DN8</title><link>http://www.csanyigroup.com/gas-insulated-switchgear-type-8dn8</link> <comments>http://www.csanyigroup.com/gas-insulated-switchgear-type-8dn8#comments</comments> <pubDate>Tue, 24 Nov 2009 21:51:13 +0000</pubDate> <dc:creator>ecsanyi</dc:creator> <category><![CDATA[High Voltage]]></category> <category><![CDATA[Technical Articles]]></category> <category><![CDATA[8DN8]]></category> <category><![CDATA[earthing switch]]></category> <category><![CDATA[feeder protection]]></category> <category><![CDATA[gas-insulated]]></category> <category><![CDATA[gis]]></category> <category><![CDATA[protection]]></category> <category><![CDATA[siemens]]></category> <category><![CDATA[substation]]></category> <category><![CDATA[switchgear]]></category> <guid
isPermaLink="false">http://www.csanyigroup.com/?p=1251</guid> <description><![CDATA[A fundamental feature of Siemens gas-insulated switchgear is the high degree of versatility provided by its modular system. Depending on their respective functions, the components are housed either individually and/or combined in compressed gas-tight enclosures. With a remarkably small number of active and passive modules, all customary circuit variants are possible. Sulphur hexafluoride (SF6) is [...]]]></description> <wfw:commentRss>http://www.csanyigroup.com/gas-insulated-switchgear-type-8dn8/feed</wfw:commentRss> <slash:comments>2</slash:comments> </item> <item><title>Profix 8DJ/8DH &amp; NXPLUS C</title><link>http://www.csanyigroup.com/profix-8dj-8dh-nxplus-c</link> <comments>http://www.csanyigroup.com/profix-8dj-8dh-nxplus-c#comments</comments> <pubDate>Tue, 06 Oct 2009 21:51:00 +0000</pubDate> <dc:creator>ecsanyi</dc:creator> <category><![CDATA[Updates And Announcements]]></category> <category><![CDATA[8DH]]></category> <category><![CDATA[8DJ]]></category> <category><![CDATA[design]]></category> <category><![CDATA[NXPLUS C]]></category> <category><![CDATA[profix]]></category> <category><![CDATA[Programi]]></category> <category><![CDATA[siemens]]></category> <category><![CDATA[srednjenaponsko postrojenje]]></category> <guid
isPermaLink="false">http://www.csanyigroup.com/?p=1109</guid> <description><![CDATA[Na stranici Stručni programi su postavljeni linkovi za download programa za specificiranje srednjenaponskih distributivnih postrojenja 8DJ, 8DH i NXPLUS C proizvođača Siemens. Programi koriste jednostavan interfejs i imaju mogućnost kreiranja porudžbina direktno u SAP-u. Postoj predefinisane kombinacije vodnih, trafo, prekidačkih i merne ćelije, kao i export izveštaja, tj. detaljnog crteža sa prednjim izgledom i otvorima [...]]]></description> <wfw:commentRss>http://www.csanyigroup.com/profix-8dj-8dh-nxplus-c/feed</wfw:commentRss> <slash:comments>1</slash:comments> </item> <item><title>SIEMENS: Short Circuit Calculations</title><link>http://www.csanyigroup.com/siemens-short-circuit-calculations</link> <comments>http://www.csanyigroup.com/siemens-short-circuit-calculations#comments</comments> <pubDate>Sun, 09 Aug 2009 22:02:19 +0000</pubDate> <dc:creator>ecsanyi</dc:creator> <category><![CDATA[Low Voltage]]></category> <category><![CDATA[Technical Articles]]></category> <category><![CDATA[calculations]]></category> <category><![CDATA[IEC]]></category> <category><![CDATA[short circuit]]></category> <category><![CDATA[siemens]]></category> <guid
isPermaLink="false">http://www.csanyigroup.com/?p=1046</guid> <description><![CDATA[Book with graphical explanations of short circuit and its calculations (purpose, standards, types, calculations&#8230;) . Related articles]]></description> <wfw:commentRss>http://www.csanyigroup.com/siemens-short-circuit-calculations/feed</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>Brendiranje el. opreme</title><link>http://www.csanyigroup.com/brendiranje-el-opreme</link> <comments>http://www.csanyigroup.com/brendiranje-el-opreme#comments</comments> <pubDate>Sat, 24 May 2008 19:42:02 +0000</pubDate> <dc:creator>ecsanyi</dc:creator> <category><![CDATA[ePlusMenuCAD]]></category> <category><![CDATA[abb]]></category> <category><![CDATA[brend]]></category> <category><![CDATA[Proizvođači opreme]]></category> <category><![CDATA[projekat]]></category> <category><![CDATA[projektant]]></category> <category><![CDATA[schneider]]></category> <category><![CDATA[schrack]]></category> <category><![CDATA[siemens]]></category> <guid
isPermaLink="false">http://www.csanyigroup.com/?p=9</guid> <description><![CDATA[Svi elementi unutar ePlusMenuCAD-a se mogu &#8220;brendirati&#8221;. To bi značilo da ti elementi jednoznačno određuju da je u pitanju određeni proizvođač opreme. To može biti Schneider Electric, ABB, Siemens, Legrand, Schrack, ili bilo koji drugi domaći ili strani proizvođač elektroopreme. Zašto to raditi? Proizvođači opreme VRLO dobro znaju da ako hoće da se njihova oprema [...]]]></description> <wfw:commentRss>http://www.csanyigroup.com/brendiranje-el-opreme/feed</wfw:commentRss> <slash:comments>1</slash:comments> </item> </channel> </rss>
